Wednesday, October 24, 2012

Mechanical Drawing of Gas Sensors on Paper

  1. Dr. Katherine A. Mirica, 
  2. Jonathan G. Weis,
  3. Dr. Jan M. Schnorr, 
  4. Dr. Birgit Esser, 
  5. Prof. Dr. Timothy M. Swager
http://onlinelibrary.wiley.com/doi/10.1002/anie.201206069/pdf


Commerically bought single-walled carbon nanotubes was compressed into a pellet and applied by mechanical abrasion to four types of paper deposited with gold electrodes. The SWCNT coated paper with the lowest surface roughness (weighing paper) had the best sensitivity toward NH3 gas. 
    

Thumbnail image of graphical abstract

No comments: